Understand the all-hazards obligation
Article 21(1) of Directive (EU) 2022/2555 addresses security risks to systems and their physical environment. An organisation therefore needs to consider power loss, fire, flooding, theft, tampering and unauthorised facility access alongside digital attacks.
The controls required at a small office, shared data centre and industrial control site may differ substantially. Determine the affected critical services and consequences of disruption before selecting measures.
Map facilities and responsibilities
Identify locations containing critical networking, servers, backups, operational technology and recovery resources. Record site owners, landlord or data-centre responsibilities, visitor arrangements and dependencies on utilities or building systems.
Assess whether suppliers operate the physical sites or provide essential access and environmental services. Outsourcing facilities does not eliminate the need to understand and evaluate security dependencies.
Control entry and sensitive equipment access
Restrict access to rooms and equipment according to duties, keep visitor authorisations proportionate, and review badges or physical keys after role changes and departures. Ensure emergency responders can gain authorised access when needed.
Cameras, alarms and access logs can provide evidence, but their operation must respect privacy and employment law. Avoid collecting recordings without a defined purpose and retention approach.
Prepare for environmental and utility failures
Consider fire detection and suppression, cooling, leak protection, resilient power, cable routing and protection against local hazards. Evaluate what the selected measures will actually do during a realistic outage.
Coordinate physical protections with business continuity objectives. For example, backup power may keep equipment running temporarily, but service availability could still fail if cooling or communications dependencies are lost.
Test, document and improve protection
Conduct appropriate inspections, access reviews, drills and recovery tests. Record limitations such as a data centre that cannot be entered for direct testing, and seek suitable assurance from the operator.
Track corrective actions, owners and verified completion. Check Member State implementing law and any sector-specific standards before calling a particular physical control mandatory for every NIS2 entity.
Points of clarification
Does NIS2 prescribe one identical procedure for every organisation?
No. Appropriate measures depend on the services, risks, Member State law and any applicable sector-specific requirements.
Are written policies enough to demonstrate controls are effective?
No. Evidence should include implementation, relevant assessment results, identified weaknesses and verified corrective actions.