Determine responsibilities and legal scope
Identify whether the entity operates the data centre, leases space, uses colocation or relies on hosted services. Map which critical systems and customer services depend on each site and which controls remain under the organisation's authority.
NIS2 distinguishes provider categories and applies through national law. Commission Implementing Regulation (EU) 2024/2690 adds detailed requirements for specified digital and ICT provider entities; those should not be described as automatically binding on every NIS2-covered organisation.
Control facility and equipment access
Define authorised entry to critical rooms, racks and maintenance areas, including arrangements for visitors, emergency staff and supplier engineers. Review badges, physical keys and escort requirements after changes in duties or contracts.
Access records can support investigation and assurance, but must be handled under applicable privacy and retention rules. Verify that entry restrictions work rather than relying solely on an access-control policy.
Plan for power, cooling and environmental faults
Assess electrical distribution, backup power, cooling, fire protection, water intrusion and site-specific risks. Consider shared points of failure that could defeat redundant equipment, along with dependencies outside the building.
Compare resilience designs with actual service recovery objectives. A generator maintenance report alone does not establish that a business service can remain available through an extended utility outage.
Assess third-party and cross-site dependencies
Review contractual service commitments, incident contacts, maintenance windows and the evidence suppliers can provide. Define the process for communicating facility events to incident responders and business continuity teams.
If recovery depends on a second site, test the ability to move services and retrieve keys, access credentials and necessary configuration information under realistic conditions.
Test assurance and document limitations
Use appropriate inspections, access reviews, service exercises and independent assurance evidence. Record where physical access or direct inspection is restricted by the provider and what alternative evidence is available.
Track material weaknesses to owners and verified remediation. Review changes to facilities, supplier arrangements and national guidance before assuming the previous assessment remains current.
Points of clarification
Does NIS2 prescribe the same technical configuration for every covered organisation?
No. Appropriate measures depend on identified risk, relevant services, Member State law and any applicable sector-specific requirements.
Can a policy alone prove that a technical control works?
No. Relevant implementation records and effectiveness assessments provide stronger assurance.